recordReformEIRChiller_Trane_CVHF_2567kW_11_77COP_VSD
ReformEIRChiller Trane CVHF 2567kW/11.77COP/VSD
A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.
Information
Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
ReformEIRChiller Trane CVHF 2567kW/11.77COP/VSD, !- Name
2567100, !- Reference Capacity {W}
11.77, !- Reference COP {W/W}
4.44, !- Reference Leaving Chilled Water Temperature {C}
17.18, !- Reference Leaving Condenser Water Temperature {C}
0.12113, !- Reference Chilled Water Flow Rate {m3/s}
0.15142, !- Reference Condenser Water Flow Rate {m3/s}
ReformEIRChiller Trane CVHF 2567kW/11.77COP/VSD CAPFT, !- Cooling Capacity Function of Temperature Curve Name
ReformEIRChiller Trane CVHF 2567kW/11.77COP/VSD EIRFT, !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
ReformEIRChiller Trane CVHF 2567kW/11.77COP/VSD EIRFPLR, !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
0.11, !- Minimum Part Load Ratio
1.04, !- Maximum Part Load Ratio
1.0, !- Optimum Part Load Ratio
0.11, !- Minimum Unloading Ratio
Chilled Water Side Inlet Node, !- Chilled Water Inlet Node Name
Chilled Water Side Outlet Node, !- Chilled Water Outlet Node Name
Condenser Side Inlet Node, !- Condenser Inlet Node Name
Condenser Side Outlet Node, !- Condenser Outlet Node Name
1.0, !- Compressor Motor Efficiency
2.0, !- Leaving Chilled Water Lower Temperature Limit {C}
ConstantFlow, !- Chiller Flow Mode Type
0.0; !- Design Heat Recovery Water Flow Rate {m3/s}
Attributes
| Name | Value |
|---|---|
| QEva_flow_nominal | -2567100 |
| COP_nominal | 11.77 |
| PLRMin | 0.11 |
| PLRMinUnl | 0.11 |
| PLRMax | 1.04 |
| mEva_flow_nominal | 1000*0.12113 |
| mCon_flow_nominal | 1000*0.15142 |
| TEvaLvg_nominal | 273.15 + 4.44 |
| TConLvg_nominal | 273.15 + 17.18 |
| TEvaLvgMin | 273.15 + 4.44 |
| TEvaLvgMax | 273.15 + 8.89 |
| TConLvgMin | 273.15 + 17.02 |
| TConLvgMax | 273.15 + 35.24 |
| capFunT | {3.150690E-01, 7.668658E-03, -4.348521E-03, 4.998865E-02, -1.242078E-03, 3.158318E-03} |
| EIRFunT | {3.654848E-01, -3.708915E-02, -7.448564E-04, 4.585429E-02, 1.719990E-04, -3.518960E-04} |
| EIRFunPLR | {-2.955643E-01, 2.586243E-02, 3.917081E-05, 7.440108E-01, 3.533880E-01, -2.797714E-02, 0.000000E+00, 2.247632E-01, 0.000000E+00, 0.000000E+00} |
| etaMotor | 1.0 |