recordReformEIRChiller_York_YT_1495kW_7_51COP_VSD

ReformEIRChiller York YT 1495kW/7.51COP/VSD

A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.

Information

Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
    ReformEIRChiller York YT 1495kW/7.51COP/VSD,  !- Name
    1494500,                 !- Reference Capacity {W}
    7.51,                    !- Reference COP {W/W}
    7.22,                    !- Reference Leaving Chilled Water Temperature {C}
    29.92,                   !- Reference Leaving Condenser Water Temperature {C}
    0.0429,                  !- Reference Chilled Water Flow Rate {m3/s}
    0.06719,                 !- Reference Condenser Water Flow Rate {m3/s}
    ReformEIRChiller York YT 1495kW/7.51COP/VSD CAPFT,  !- Cooling Capacity Function of Temperature Curve Name
    ReformEIRChiller York YT 1495kW/7.51COP/VSD EIRFT,  !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
    ReformEIRChiller York YT 1495kW/7.51COP/VSD EIRFPLR,  !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
    0.11,                    !- Minimum Part Load Ratio
    1.04,                    !- Maximum Part Load Ratio
    1.0,                     !- Optimum Part Load Ratio
    0.11,                    !- Minimum Unloading Ratio
    Chilled Water Side Inlet Node,  !- Chilled Water Inlet Node Name
    Chilled Water Side Outlet Node,  !- Chilled Water Outlet Node Name
    Condenser Side Inlet Node,  !- Condenser Inlet Node Name
    Condenser Side Outlet Node,  !- Condenser Outlet Node Name
    1.0,                     !- Compressor Motor Efficiency
    2.0,                     !- Leaving Chilled Water Lower Temperature Limit {C}
    ConstantFlow,            !- Chiller Flow Mode Type
    0.0;                     !- Design Heat Recovery Water Flow Rate {m3/s}

Attributes

NameValue
QEva_flow_nominal-1494500
COP_nominal7.51
PLRMin0.11
PLRMinUnl0.11
PLRMax1.04
mEva_flow_nominal1000*0.0429
mCon_flow_nominal1000*0.06719
TEvaLvg_nominal273.15 + 7.22
TConLvg_nominal273.15 + 29.92
TEvaLvgMin273.15 + 5.56
TEvaLvgMax273.15 + 8.89
TConLvgMin273.15 + 18.69
TConLvgMax273.15 + 41.38
capFunT{6.015487E-01, -1.630120E-01, 9.951930E-03, 7.452875E-02, -1.608224E-03, 2.001891E-03}
EIRFunT{1.954138E-01, -1.627980E-01, 5.924232E-03, 8.194832E-02, -8.723337E-04, 7.443855E-04}
EIRFunPLR{6.377828E-01, -3.620643E-02, -1.187858E-04, 5.832958E-01, -9.230655E-01, 4.307256E-02, 0.000000E+00, 6.079021E-01, 0.000000E+00, 0.000000E+00}
etaMotor1.0