modelPartialChillerCycle

Partial model of refrigerant cycle used for chiller applications

Extends from Buildings.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.BaseClasses.PartialRefrigerantCycle (Partial model of refrigerant cycle).

Information

Partial refrigerant cycle model for chillers. It adds the specification for frosting calculation and restricts to the intended choices under choicesAllMatching.

Parameters

TypeNameDefaultDescription
StringdevIde (from PartialRefrigerantCycle)""Indicates the data source, used to warn users about different vapor compression devices in reversible models
BooleanuseInChi=false to indicate that this model is used as a heat pump
Nominal condition
Modelica.Units.SI.PowerPEle_nominal (from PartialRefrigerantCycle)Nominal electrical power consumption
Modelica.Units.SI.TemperatureTCon_nominal (from PartialRefrigerantCycle)Nominal temperature at secondary condenser side
Modelica.Units.SI.TemperatureTEva_nominal (from PartialRefrigerantCycle)Nominal temperature at secondary evaporator side
Modelica.Units.SI.HeatFlowRateQCoo_flow_nominalNominal cooling capacity
Advanced › Medium properties
Modelica.Units.SI.SpecificHeatCapacitycpCon (from PartialRefrigerantCycle)Evaporator medium specific heat capacity
Modelica.Units.SI.SpecificHeatCapacitycpEva (from PartialRefrigerantCycle)Evaporator medium specific heat capacity

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutputPEle (from PartialRefrigerantCycle)Electrical Power consumed by the device
Modelica.Blocks.Interfaces.RealOutputQCon_flow (from PartialRefrigerantCycle)Heat flow rate through condenser
Buildings.Fluid.HeatPumps.ModularReversible.BaseClasses.RefrigerantMachineControlBussigBus (from PartialRefrigerantCycle)Bus-connector
Modelica.Blocks.Interfaces.RealOutputQEva_flow (from PartialRefrigerantCycle)Heat flow rate through evaporator

Components

TypeNameDefaultDescription
Buildings.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.Frosting.NoFrostingiceFacCal (from PartialRefrigerantCycle)
Modelica.Blocks.Math.AddredQCon (from PartialRefrigerantCycle)Reduce heat flow to the condenser based on the reduction to the evaporator
Modelica.Blocks.Math.ProductproRedQEva (from PartialRefrigerantCycle)Reduce heat flow to the evaporator based on the icing factor

Revisions

  • October 2, 2022 by Fabian Wuellhorst:
    Adapted based on Buildings implementation (see issue #1576)
  • October 2, 2022 by Fabian Wuellhorst:
    First implementation (see issue #1576)