recordNominalValues

Data record of nominal values

Extends from Modelica.Icons.Record (Icon for records).

Information

This is the base record of nominal values for air source DX heating coil models.

See the information section of Buildings.Fluid.DXSystems.Heating.AirSource.Data.Generic.DXCoil for a description of the data.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TimetWet0Time until moisture drips from coil when a dry coil is switched on
Realgamma0Ratio of evaporation heat transfer divided by latent heat transfer at nominal conditions
Nominal condition
Modelica.Units.SI.HeatFlowRateQ_flow_nominalNominal capacity
RealCOP_nominalNominal coefficient of performance
Modelica.Units.SI.MassFlowRatem_flow_nominalNominal air mass flow rate at evaporators
RealSHR_nominal0Nominal sensible heat ratio
General › Nominal condition
Modelica.Units.SI.TemperatureTEvaIn_nominal292.55Evaporator entering air wet-bulb temperature at rating condition
Modelica.Units.SI.TemperatureTConIn_nominal308.15Condenser entering temperature at rating condition
Modelica.Units.SI.Pressurep_nominal101325Atmospheric pressure
General › Nominal
RealphiIn_nominal0.5Relative humidity of entering air at nominal condition

Revisions

  • May 16, 2023 by Michael Wetter:
    First implementation.