connectorRadiosityInflow
Connector for inflowing radiosity
A connector of Real.
Information
The nominal value is set to σ T4 = σ 293.154 = 419.Attributes
| Name | Value |
|---|---|
| min | 0 |
| unit final | "W" |
| nominal | 419 |
Revisions
-
June 27, 2013, by Michael Wetter:
Removedflowattribute as this violates the Modelica Language Standard. See track issue #158. -
September 3, 2010, by Michael Wetter:
First implementation.