modelSteamTemperatureEnthalpyInversion

Model to check computation of h(T) and its inverse

Extends from Modelica.Icons.Example (Icon for runnable examples), Buildings.Media.Examples.BaseClasses.TestTemperatureEnthalpyInversion (Model to check computation of h(T) and its inverse with a controlleable tolerance).

Information

This model tests whether the inversion of temperature and enthalpy is implemented correctly for the steam model.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureT0 (from TestTemperatureEnthalpyInversion)273.15 + 20Temperature
Realtol (from TestTemperatureEnthalpyInversion)1E-8Numerical tolerance

Components

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureT (from TestTemperatureEnthalpyInversion)Temperature
Modelica.Units.SI.SpecificEnthalpyh (from TestTemperatureEnthalpyInversion)Enthalpy
Medium.MassFraction[:]Xi (from TestTemperatureEnthalpyInversion)Medium.reference_XMass fraction

Revisions

  • March 24, 2020, by Kathryn Hinkelman:
    Relaxed absolute error tolerance.
  • January 16, 2020, by Kathryn Hinkelman:
    Change medium to ideal steam to eliminate property discontinuities.
  • September 12, 2019, by Yangyang Fu:
    First implementation.