recordCellAndElectricalDividingWall

Wall separating FLEXLAB test cells from the adjoining electrical rooms

A record of Buildings.HeatTransfer.Data.OpaqueConstructions.Generic.

Information

This is a construction of a dividing wall commonly found in FLEXLAB test cells. It is used to divide one test cell from another (cell A and cell B) as well as separate the test cell from the connected electrical room.

Attributes

NameValue
material final{Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.127), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.0127), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.2032), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.0127), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.01905)}
nLay final5

Revisions

  • September 17, 2013, by Peter Grant:
    First implementation.