recordTestBedDividingWall

Wall separating test beds

A record of Buildings.HeatTransfer.Data.OpaqueConstructions.Generic.

Information

This is a dividing wall commonly found in FLEXLAB test cells. It is used to separate one test cell from another (For example, it is found between test cells X2B and X3A).

Attributes

NameValue
material final{Buildings.HeatTransfer.Data.Solids.GypsumBoard(x = 0.01588), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.1016), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.0127), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.2032), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.127), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.127), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.2032), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.127), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.1016), Buildings.HeatTransfer.Data.Solids.GypsumBoard(x = 0.1588)}
nLay10

Revisions

  • September 17, 2013, by Peter Grant:
    First implementation.