recordTestCellDividngWall
Wall separating test cells within a test bed
A record of Buildings.HeatTransfer.Data.OpaqueConstructions.Generic.
Information
This is a dividing wall used to separate test cells within a given test bed. For example, it is installed between test cells X3A and X3B.
Attributes
| Name | Value |
|---|---|
| material final | {Buildings.HeatTransfer.Data.Solids.GypsumBoard(x = 0.01588), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.1016), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.0127), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.2032), Buildings.HeatTransfer.Data.Solids.Plywood(x = 0.127), Buildings.HeatTransfer.Data.Solids.InsulationBoard(x = 0.1016), Buildings.HeatTransfer.Data.Solids.GypsumBoard(x = 0.1588)} |
| nLay | 7 |
Revisions
-
September 17, 2013, by Peter Grant:
First implementation.