modelEquipmentSchedule
Example model with a schedule that overrides a schedule in EnergyPlus
Extends from Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.Unconditioned (Example model with one unconditoned zone simulated in Modelica, and the other two unconditioned zones simulated in EnergyPlus).
Information
Example model that demonstrates how to override a schedule in EnergyPlus.
The model overrides the EnergyPlus schedule INTERMITTENT,
which is used by EnergyPlus to control the equipment in the thermal zone.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Volume | VRoo (from Unconditioned) | 453.1 | Room volume |
| Modelica.Units.SI.MassFlowRate | m_flow_nominal (from Unconditioned) | VRoo*1.2*0.3/3600 | Nominal mass flow rate |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Buildings.ThermalZones.EnergyPlus_24_2_0.Building | building (from Unconditioned) | Building model | |
| Buildings.ThermalZones.EnergyPlus_24_2_0.ThermalZone | zon (from Unconditioned) | Thermal zone | |
| Buildings.Fluid.FixedResistances.PressureDrop | duc (from Unconditioned) | Duct resistance (to decouple room and outside pressure) | |
| Buildings.Fluid.Sources.MassFlowSource_WeatherData | bou (from Unconditioned) | Boundary condition | |
| Buildings.Fluid.Sources.Boundary_pT | freshAir (from Unconditioned) | Boundary condition | |
| Modelica.Blocks.Sources.Constant[3] | qIntGai (from Unconditioned) | Internal heat gains, set to zero because these are modeled in EnergyPlus | |
| Buildings.ThermalZones.EnergyPlus_24_2_0.Schedule | schInt | Block that writes to the EnergyPlus schedule INTERMITTENT | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Pulse | intLoaFra | Schedule for fraction of internal loads |
Revisions
-
May 21, 2020, by Michael Wetter:
First implementation.