modelNoOutputVariable

Failing example caused by missing Output:Variable in the idf

Extends from Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.Unconditioned (Example model with one unconditoned zone simulated in Modelica, and the other two unconditioned zones simulated in EnergyPlus).

Information

This validation case tests whether Spawn works for an idf file that has no output variables declared.

The model is identical to Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.Unconditioned except that it uses an idf file that has no output variables.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.VolumeVRoo (from Unconditioned)453.1Room volume
Modelica.Units.SI.MassFlowRatem_flow_nominal (from Unconditioned)VRoo*1.2*0.3/3600Nominal mass flow rate

Components

TypeNameDefaultDescription
Buildings.ThermalZones.EnergyPlus_24_2_0.Buildingbuilding (from Unconditioned)Building model
Buildings.ThermalZones.EnergyPlus_24_2_0.ThermalZonezon (from Unconditioned)Thermal zone
Buildings.Fluid.FixedResistances.PressureDropduc (from Unconditioned)Duct resistance (to decouple room and outside pressure)
Buildings.Fluid.Sources.MassFlowSource_WeatherDatabou (from Unconditioned)Boundary condition
Buildings.Fluid.Sources.Boundary_pTfreshAir (from Unconditioned)Boundary condition
Modelica.Blocks.Sources.Constant[3]qIntGai (from Unconditioned)Internal heat gains, set to zero because these are modeled in EnergyPlus

Revisions

  • June 1, 2021, by Baptiste Ravache:
    First implementation.
    This is for issue 2512.