classVersion_13_0_1

Version 13.0.1

Extends from Modelica.Icons.ReleaseNotes (Icon for release notes in documentation).

Information

Version 13.0.1 is ... xxx

The following new libraries have been added:

xxx xxx.
Buildings.Controls.OBC.ASHRAE.G36.Plants Package of sequences for chiller plants

The following new components have been added to existing libraries:

xxx
xxx xxx.

The following existing components have been improved in a backward compatible way:

xxx
xxx xxx.
Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart
Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.BaseClasses.ZoneWithAHUConventional
Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.BaseClasses.ZoneWithAHUG36
Changed the class type from block to model.
This is for Buildings, issue 4606.
Buildings.HeatTransfer.Windows
Buildings.HeatTransfer.Windows.BaseClasses.Overhang Changed the class type from block to model.
This is for Buildings, issue 4606.
Buildings.BoundaryConditions
Buildings.BoundaryConditions.SolarGeometry.IncidenceAngle
Buildings.BoundaryConditions.SolarGeometry.ZenithAngle
Buildings.BoundaryConditions.SolarIrradiation.DiffuseIsotropic
Buildings.BoundaryConditions.SolarIrradiation.DiffusePerez
Buildings.BoundaryConditions.SolarIrradiation.DirectTiltedSurface
Buildings.BoundaryConditions.SolarIrradiation.GlobalPerezTiltedSurface
Changed the class type from block to model.
This is for IBPSA, issue 2122.
Buildings.Controls.OBC.CDL
Buildings.Controls.OBC.CDL.Integers.Change
Buildings.Controls.OBC.CDL.Logical.Change
Replaced initial equation with start attribute on input.
This is for Buildings, issue 4581.
Buildings.ThermalZones.Detailed
Buildings.ThermalZones.Detailed.Examples.FFD Improved C source codes and recompiled FFD library to allow the examples being simulated with OpenModelica.
This is for Buildings, #4015.
Buildings.Fluid.Sources
Buildings.Fluid.Sources.BaseClasses.PartialSource
Buildings.Fluid.Sources.BaseClasses.PartialAirSource
Removed deprecated cardinality function.
Removed protected parameter flowDirection as it was set to Bidirectional and had no effect on the model. The annoation mayOnlyConnectOnce must not be used for these models as they are often used to set the reference presssure in closed system flow networks.
This is for Buildings, #4607.
Buildings.Fluid.Sources.TraceSubstancesFlowSource Removed deprecated cardinality function and replaced with mayOnlyConnectOnce annotation.
Removed protected parameter flowDirection as it was set to Bidirectional and had no effect on the model.
This is for Buildings, #4607.
Buildings.ThermalZones.EnergyPlus_24_2_0
Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.MultipleBuildings Improved C source codes to allow the validation model being simulated with OpenModelica.
This is for Buildings, #3345.
Buildings.ThermalZones.EnergyPlus_24_2_0.OpaqueConstruction Removed deprecated cardinality function and replaced with mustBeConnected annotation.
This is for Buildings, #4607.
Buildings.Utilities.IO.BCVTB
Buildings.Utilities.IO.BCVTB.BaseClasses.FluidInterface Removed protected parameter flowDirection as it was set to Bidirectional and had no effect on the model.
This is for Buildings, #4607.

The following existing components have been improved in a non-backward compatible way:

xxx
xxx xxx.

The following critical errors have been fixed (i.e., errors that can lead to wrong simulation results):

xxx
xxx xxx.

The following uncritical errors have been fixed (i.e., errors that do not lead to wrong simulation results, e.g., units are wrong or errors in documentation):

xxx
xxx xxx.

Note:

  • xxx