Model description: A stationary flame room model for fuel fired furnaces with additional air port
Contact: Lasse Nielsen, TLK-Thermo GmbH
FEATURES
- This model uses TILMedia
- Stationary mass and energy balances are used
- Additional air port for secondary air
- The formation enthalpy of the used fuel is calculated with the given Lower heating value and and ideal combustion with the given elemental composition of the fuel
- Lower heating can be regarded with a fixed value or calculated according to the "Verbandsformel"
- Different heat transfer correlations can be chosen
- Capable to burn unburnt fuel from lower burner sections
- Amount of burnable fuel mass is calculated with particle diffusity which depends on models used to determine the mean migration speed according to the volume flow rates of the flue gas
Generated at 2024-11-21T19:25:40Z
by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos