modelPartialBasicElectricMachine2ph_wBalance

Basic model for two-phase electric machines (using current phasor balance, but no power calculation)

Extends from PartialBasicMachine (Basic model for generalized electric machines).

Information

This partial model is an extension of the model of a generalized electric machine PartialBasicMachine. Hence, it consists of the same mechanical subsystem. The model defines a two-phase machine. The electrical subsystem contains four electrical pins of type ComplexPin.
The rms values of the branch voltages and branch currents are calculated from the corresponding phasors. The model does include the current phasor balance. Therefore, models being extended from PartialBasicElectricMachine2ph_wBalance must not contain any internal electrical components. The behaviour of such models has to be defined by equations. The model does not include any power calculation.

Remark:
This partial model is suitable only for modeling two-phase machines.

Main Author:
Olaf Enge-Rosenblatt
Fraunhofer IIS/EAS, Dresden
email: olaf.enge@eas.iis.fraunhofer.de

Parameters

TypeNameDefaultDescription
Modelica.SIunits.InertiaJ_Rotor (from PartialBasicMachine)1Rotor's moment of inertia
Integerm2Number of phases

Connectors

TypeNameDefaultDescription
Modelica.Mechanics.Rotational.Interfaces.Flange_ashaft (from PartialBasicMachine)Flange at shaft
ComplexLib.SinglePhase.Interfaces.PosComplexPinp1Positive complex pin no.1
ComplexLib.SinglePhase.Interfaces.PosComplexPinp2Positive complex pin no.2
ComplexLib.SinglePhase.Interfaces.NegComplexPinn1Negative complex pin no.1
ComplexLib.SinglePhase.Interfaces.NegComplexPinn2Negative complex pin no.2

Components

TypeNameDefaultDescription
Modelica.Mechanics.Rotational.Components.InertiainertiaRotor (from PartialBasicMachine)
Modelica.Mechanics.Rotational.Components.FixedfixedHousing (from PartialBasicMachine)
SI.Voltage[m]vVoltages between the two plugs
SI.Voltage[m]vReActive parts of voltage phasors
SI.Voltage[m]vImReactive parts of voltage phasors
SI.Current[m]iCurrents flowing into positive plug
SI.Current[m]iReActive parts of current phasors
SI.Current[m]iImReactive parts of current phasors