Ideal linear electrical inductors for phasor analysis
The model contains m linear inductors.
Inductor no. k connects the branch voltage phasor v[k]
with the corresponding branch current phasor i[k] by
jωL[k]*i[k] = v[k]
(k=1...m).
All inductances L[k] are constant values.