.ComplexLib.SinglePhase.Basic.Transformers.VariablePowerTransformer

Information

The VariablePowerTransformer is a two port with variable parameters. The left port voltage v1, left port current i1, right port voltage v2 and right port current i2 are connected by the following relations:

      v1  = R1 *i1  + jωL_1s *i1  + R_Fe*jωL_h/(R_Fe + jωL_h)*(i1 + i2')
      v2' = R2'*i2' + jωL_2s'*i2' + R_Fe*jωL_h/(R_Fe + jωL_h)*(i1 + i2')

with:

      v2'=w1_w2*v2;  i2'=i2/w1_w2;  L_2s'=(w1_w2)^2*L_2s;  R2'=(w1_w2)^2*R2

This is the common way to describe power transformers.
All parameters are specified by independent input signals.

Attention!!!
To ensure that the phasor domain-based model works in a quasi-stationary mode, all input signals may alter only very slowly in comparison with both the nominal frequency f=ω/(2π) and the dominant time constant of the phasor domain-based model.

Main Authors:
Matthias Vetter, Simon Schwunk
Fraunhofer ISE, Freiburg
email: matthias.vetter@ise.fraunhofer.de
and
Olaf Enge-Rosenblatt
Fraunhofer IIS/EAS, Dresden
email: olaf.enge@eas.iis.fraunhofer.de