.ComplexLib.SinglePhase.Sources.SignalVoltage

Information

A sinusoidal voltage source in time-domain corresponds to an applied voltage phasor v in phasor analysis. In the SignalVoltage component, the effective (or rms) value V and the phase angle phase of the applied voltage phasor are not forced to be constant values. Hence, these values are specified by input signals.

Attention!!!
To ensure that the phasor domain-based model works in a quasi-stationary mode, both rms value and phase angle may alter only very slowly in comparison with both the nominal frequency f=ω/(2π) and the dominant time constant of the phasor domain-based model.

Main Authors:
Matthias Vetter, Simon Schwunk
Fraunhofer ISE, Freiburg
email: matthias.vetter@ise.fraunhofer.de
and
Olaf Enge-Rosenblatt
Fraunhofer IIS/EAS, Dresden
email: olaf.enge@eas.iis.fraunhofer.de


Generated at 2024-05-08T18:15:54Z by OpenModelicaOpenModelica 1.22.4 using GenerateDoc.mos