modelBasePControl4

Base active power control module for type 4 wind turbines (IEC N°61400-27-1)

Parameters

TypeNameDefaultDescription
Types.ApparentPowerModuleSNomNominal converter apparent power in MVA
PControl
Types.PerUnitKpawAnti-windup gain for the integrator of the ramp-limited first order in pu/s (base SNom)
Initialization
Types.PerUnitIpMax0PuInitial maximum active current at converter terminal in pu (base UNom, SNom) (generator convention)
Operating point
Types.ActivePowerPuP0PuInitial active power at grid terminal in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU0PuInitial voltage amplitude at grid terminal in pu (base UNom)

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputipMaxPuMaximum active current at converter terminal in pu (base UNom, SNom) (generator convention)
Modelica.Blocks.Interfaces.RealInputPWTRefPuActive power reference at grid terminal in pu (base SNom) (generator convention)
Modelica.Blocks.Interfaces.RealOutputipCmdPuActive current command at converter terminal in pu (base UNom, SNom) (generator convention)

Components

TypeNameDefaultDescription
Modelica.Blocks.Math.Productproduct1
Modelica.Blocks.Math.Divisiondivision
Modelica.Blocks.Math.Maxmax
Modelica.Blocks.Sources.Constantconst
Dynawo.NonElectrical.Blocks.Continuous.AbsLimRateLimFirstOrderAntiWindupabsLimRateLimFirstOrderAntiWindup
Modelica.Blocks.Sources.Constantconst2