modelElecMeasurements
This block measures the voltage and current in pu (base UNom, SNom)
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Dynawo.Types.ApparentPowerModule | SNom | Nominal converter apparent power in MVA |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Dynawo.Connectors.ACPower | terminal1 | Terminal 1, complex voltage and current in pu (base UNom, SnRef) (receptor convention) | |
| Dynawo.Connectors.ACPower | terminal2 | Terminal 2, complex voltage and current in pu (base UNom, SnRef) (receptor convention) | |
| Modelica.ComplexBlocks.Interfaces.ComplexOutput | iPu | Complex current at terminal 1 in pu (base UNom, SNom) (generator convention) | |
| Modelica.Blocks.Interfaces.RealOutput | PPu | Active power P at terminal 1 in pu (base SNom) (generator convention) | |
| Modelica.Blocks.Interfaces.RealOutput | PPuSnRef | Active power P at terminal 1 in pu (base SnRef) (generator convention) | |
| Modelica.Blocks.Interfaces.RealOutput | QPu | Reactive power Q at terminal 1 in pu (base SNom) (generator convention) | |
| Modelica.Blocks.Interfaces.RealOutput | QPuSnRef | Reactive power Q at terminal 1 in pu (base SnRef) (generator convention) | |
| Modelica.ComplexBlocks.Interfaces.ComplexOutput | uPu | Complex voltage at terminal 1 in pu (base UNom) |