| Types.PerUnit | Ka | | Voltage regulator gain |
| Types.PerUnit | Kas | | Power converter gain proportional to supply voltage |
| Types.PerUnit | Kc | | Rectifier loading factor proportional to commutating reactance |
| Types.PerUnit | Ki | | Potential circuit (current) gain coefficient |
| Types.PerUnit | Kp | | Potential circuit gain |
| Types.PerUnit | Ku | | Gain associated with activation of takeover UEL |
| Integer | PositionOel | | Input location : (0) none, (1) voltage error summation, (2) take-over |
| Integer | PositionScl | | Input location : (0) none, (1) voltage error summation, (2) take-over |
| Integer | PositionUel | | Input location : (0) none, (1) voltage error summation, (2) take-over |
| Boolean | Sw1 | | If true, power source derived from terminal voltage, if false, independent from terminal voltage |
| Types.Time | tA | | Voltage regulator time constant in s |
| Types.Time | tAs | | Equivalent time constant of power converter firing control in s |
| Types.Time | tAUel | | Time constant of underexcitation limiter in s |
| Types.Time | tBd | | Filter time constant of differential part of voltage regulator in s |
| Types.Time | tCd | | Time constant of differential part of voltage regulator in s |
| Types.Angle | Thetap | | Potential circuit phase angle in rad |
| Types.Time | tR | | Stator voltage filter time constant in s |
| Types.VoltageModulePu | VbMaxPu | | Maximum available exciter field voltage in pu (base UNom) |
| Types.VoltageModulePu | VrMaxPu | | Maximum field voltage in pu (user-selected base voltage) |
| Types.VoltageModulePu | VrMinPu | | Minimum field voltage in pu (user-selected base voltage) |
| Types.PerUnit | XlPu | | Reactance associated with potential source in pu (base SNom, UNom) |
| Types.VoltageModulePu | ZaPu | | Dead-band for differential part influence on voltage regulator in pu (base UNom) |
| Types.VoltageModulePu | Efd0Pu | | Initial excitation voltage in pu (user-selected base voltage) |
| Types.CurrentModulePu | Ir0Pu | | Initial rotor current in pu (base SNom, user-selected base voltage) |
| Types.ComplexCurrentPu | it0Pu | | Initial complex stator current in pu (base SNom, UNom) |
| Types.VoltageModulePu | Us0Pu | | Initial stator voltage in pu (base UNom) |
| Types.ComplexVoltagePu | ut0Pu | | Initial complex stator voltage in pu (base UNom) |
| Types.VoltageModulePu | UOel0Pu | 0 | Overexcitation limitation initial output voltage in pu (base UNom) |
| Types.VoltageModulePu | USclOel0Pu | 0 | Stator current overexcitation limitation initial output voltage in pu (base UNom) |
| Types.VoltageModulePu | USclUel0Pu | 0 | Stator current underexcitation limitation initial output voltage in pu (base UNom) |
| Types.VoltageModulePu | UUel0Pu | 0 | Underexcitation limitation initial output voltage in pu (base UNom) |
| Types.VoltageModulePu | Vb0Pu | | Initial available exciter field voltage in pu (base UNom) |