modelLoadAlphaBetaRestorativeLimitsRecalc_INIT

Initialization model for restorative alpha-beta load with a limits recalculation

Extends from Load_INIT (Initialization for load from load-flow outputs).

Parameters

TypeNameDefaultDescription
Types.ActivePowerPuP0Pu (from Load_INIT)Start value of active power in pu (base SnRef) (receptor convention)
Types.ReactivePowerPuQ0Pu (from Load_INIT)Start value of reactive power in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU0Pu (from Load_INIT)Start value of voltage amplitude at load terminal in pu (base UNom)
Types.AngleUPhase0 (from Load_INIT)Start value of voltage angle at load terminal (in rad)
Types.VoltageModulePuUMin0PuMinimum value of the voltage amplitude at terminal in pu (base UNom) that ensures the P/Q restoration
Types.VoltageModulePuUMax0PuMaximum value of the voltage amplitude at terminal in pu (base UNom) that ensures the P/Q restoration
Types.VoltageModulePuUDeadBandPuDeadband of the limits recalculation in pu (base UNom)

Components

TypeNameDefaultDescription
Types.ComplexVoltagePuu0Pu (from Load_INIT)Start value of complex voltage at load terminal in pu (base UNom)
Types.ComplexApparentPowerPus0Pu (from Load_INIT)Start value of complex apparent power in pu (base SnRef) (receptor convention)
Types.ComplexCurrentPui0Pu (from Load_INIT)Start value of complex current at load terminal in pu (base UNom, SnRef) (receptor convention)
Types.VoltageModulePuUMinPuRecalculated minimum value of the voltage amplitude at terminal in pu (base UNom) that ensures the P/Q restoration
Types.VoltageModulePuUMaxPuRecalculated maximum value of the voltage amplitude at terminal in pu (base UNom) that ensures the P/Q restoration