modelMotorFifthOrder_INIT

Initialization model for MotorFifthOrder

Extends from BaseClasses_INIT.BaseMotor_INIT (Base initialisation model of motors), AdditionalIcons.Init.

Parameters

TypeNameDefaultDescription
Types.ApparentPowerModuleSNom (from BaseMotor_INIT)Nominal apparent power of the motor in MVA
Types.ActivePowerPuP0Pu (from BaseMotor_INIT)Start value of active power in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU0Pu (from BaseMotor_INIT)Start value of voltage amplitude at load terminal in pu (base UNom)
Types.AngleUPhase0 (from BaseMotor_INIT)Start value of voltage angle at load terminal (in rad)
Types.PerUnitRsPuStator resistance in pu (base SNom, UNom)
Types.PerUnitLsPuSynchronous reactance in pu (base SNom, UNom)
Types.PerUnitLPPuTransient reactance in pu (base SNom, UNom)
Types.PerUnitLPPPuSubtransient reactance in pu (base SNom, UNom)
Types.TimetP0Transient open circuit time constant in s
Types.TimetPP0Subtransient open circuit time constant in s

Components

TypeNameDefaultDescription
Types.ComplexCurrentPui0Pu (from BaseMotor_INIT)Start value of complex current at load terminal in pu (base UNom, SnRef) (receptor convention)
Types.ReactivePowerPuQ0Pu (from BaseMotor_INIT)Start value of reactive power in pu (base SnRef) (receptor convention)
Types.ComplexApparentPowerPus0Pu (from BaseMotor_INIT)Start value of complex apparent power in pu (base SnRef) (receptor convention)
Types.ComplexVoltagePuu0Pu (from BaseMotor_INIT)Start value of complex voltage at load terminal in pu (base UNom)
Types.PerUnitEdP0PuStart value of voltage behind transient reactance d component in pu (base UNom)
Types.PerUnitEqP0PuStart value of voltage behind transient reactance q component in pu (base UNom)
Types.PerUnitEdPP0PuStart value of voltage behind subtransient reactance d component in pu (base UNom)
Types.PerUnitEqPP0PuStart value of voltage behind subtransient reactance q component in pu (base UNom)
Types.PerUnitid0PuStart value of current of direct axis in pu (base SNom, Unom)
Types.PerUnitiq0PuStart value of current of quadrature axis in pu (base SNom, Unom)
Types.AngularVelocityPuomegaR0PuStart value of the angular velocity of the motor in pu (base omegaNom)
Types.PerUnitce0PuStart value of the electrical torque in pu (base SNom, omegaNom)
Reals0Start value of the slip of the motor