modelBasePQProp
Base dynamic model for a proportional reactive power regulation
Parameters
| Type | Name | Default | Description |
| Real | QPercent | | Percentage of the coordinated reactive control that comes from this machine |
| Types.ReactivePowerPu | QRef0Pu | | Start value of the reactive power set point in pu (base SnRef) (receptor convention) |
| Types.ReactivePowerPu | QDeadBandPu | | Reactive power deadband around the target in pu (base SnRef) |
Components
| Type | Name | Default | Description |
| Types.PerUnit | NQ | | Signal to change the reactive power generation of the generator depending on the centralized distant voltage regulation (generator convention) |