modelBaseGeneratorSignalN_INIT

Base initialization model for SignalN generator models

Extends from Dynawo.Electrical.Machines.BaseClasses_INIT.BaseGeneratorParameters_INIT (Base initialization model for simplified generator models), AdditionalIcons.Init.

Parameters

TypeNameDefaultDescription
Types.ComplexCurrentPuiStart0Pu (from BaseGeneratorParameters_INIT)Complex(0, 0)Start value of complex current at terminal in pu (base UNom, SnRef) (receptor convention)
Types.ActivePowerPuP0Pu (from BaseGeneratorParameters_INIT)Start value of active power at terminal in pu (base SnRef) (receptor convention)
Types.ReactivePowerPuQ0Pu (from BaseGeneratorParameters_INIT)Start value of reactive power at terminal in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU0Pu (from BaseGeneratorParameters_INIT)Start value of voltage amplitude at terminal in pu (base UNom)
Types.AngleUPhase0 (from BaseGeneratorParameters_INIT)Start value of voltage angle at terminal in rad
Types.ActivePowerPuPMaxMaximum active power in MW
Types.ActivePowerPuPMinMinimum active power in MW
Types.ReactivePowerPuQMaxMaximum reactive power in Mvar
Types.ReactivePowerPuQMinMinimum reactive power in Mvar

Components

TypeNameDefaultDescription
Types.ActivePowerPuPGen0Pu (from BaseGeneratorParameters_INIT)Start value of active power at terminal in pu (base SnRef) (generator convention)
Types.ReactivePowerPuQGen0Pu (from BaseGeneratorParameters_INIT)Start value of reactive power at terminal in pu (base SnRef) (generator convention)
Types.ComplexVoltagePuu0Pu (from BaseGeneratorParameters_INIT)Start value of complex voltage at terminal in pu (base UNom)
Types.ComplexApparentPowerPus0Pu (from BaseGeneratorParameters_INIT)Start value of complex apparent power at terminal in pu (base SnRef) (receptor convention)
Types.ComplexCurrentPui0Pu (from BaseGeneratorParameters_INIT)Start value of complex current at terminal in pu (base UNom, SnRef) (receptor convention)
BooleanlimUQDown0Whether the minimum reactive power limits are reached or not (from generator voltage regulator), start value
BooleanlimUQUp0Whether the maximum reactive power limits are reached or not (from generator voltage regulator), start value
Types.ActivePowerPuPMaxPuMaximum active power in pu (base SnRef)
Types.ReactivePowerPuQMaxPuMaximum reactive power in pu (base SnRef)
Types.ActivePowerPuPMinPuMinimum active power in pu (base SnRef)
Types.ReactivePowerPuQMinPuMinimum reactive power in pu (base SnRef)
QStatusqStatus0Start voltage regulation status: Standard, AbsorptionMax, GenerationMax

Contents

NameDescription
QStatus