modelGeneratorPVDiagramPQSFR_INIT

Initialisation model for generator PV based on SignalN for the frequency handling, with an N points PQ diagram and that participates in the Secondary Frequency Regulation (SFR)

Extends from BaseClasses_INIT.BaseGeneratorSignalNPQDiagram_INIT (Base initialization model for SignalN generator models with PQ diagram), AdditionalIcons.Init.

Parameters

TypeNameDefaultDescription
Types.ComplexCurrentPuiStart0Pu (from BaseGeneratorParameters_INIT)Complex(0, 0)Start value of complex current at terminal in pu (base UNom, SnRef) (receptor convention)
Types.ActivePowerPuP0Pu (from BaseGeneratorParameters_INIT)Start value of active power at terminal in pu (base SnRef) (receptor convention)
Types.ReactivePowerPuQ0Pu (from BaseGeneratorParameters_INIT)Start value of reactive power at terminal in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU0Pu (from BaseGeneratorParameters_INIT)Start value of voltage amplitude at terminal in pu (base UNom)
Types.AngleUPhase0 (from BaseGeneratorParameters_INIT)Start value of voltage angle at terminal in rad
Types.ActivePowerPuPMax (from BaseGeneratorSignalNPQDiagram_INIT)Maximum active power in MW
Types.ActivePowerPuPMin (from BaseGeneratorSignalNPQDiagram_INIT)Minimum active power in MW
Types.ReactivePowerPuQMax0 (from BaseGeneratorSignalNPQDiagram_INIT)Start value of maximum reactive power in Mvar
Types.ReactivePowerPuQMin0 (from BaseGeneratorSignalNPQDiagram_INIT)Start value of minimum reactive power in Mvar
Types.VoltageModulePuURef0PuStart value of the voltage regulation set point in pu (base UNom)

Components

TypeNameDefaultDescription
Types.ActivePowerPuPGen0Pu (from BaseGeneratorParameters_INIT)Start value of active power at terminal in pu (base SnRef) (generator convention)
Types.ReactivePowerPuQGen0Pu (from BaseGeneratorParameters_INIT)Start value of reactive power at terminal in pu (base SnRef) (generator convention)
Types.ComplexVoltagePuu0Pu (from BaseGeneratorParameters_INIT)Start value of complex voltage at terminal in pu (base UNom)
Types.ComplexApparentPowerPus0Pu (from BaseGeneratorParameters_INIT)Start value of complex apparent power at terminal in pu (base SnRef) (receptor convention)
Types.ComplexCurrentPui0Pu (from BaseGeneratorParameters_INIT)Start value of complex current at terminal in pu (base UNom, SnRef) (receptor convention)
BooleanlimUQDown0 (from BaseGeneratorSignalNPQDiagram_INIT)Whether the minimum reactive power limits are reached or not (from generator voltage regulator), start value
BooleanlimUQUp0 (from BaseGeneratorSignalNPQDiagram_INIT)Whether the maximum reactive power limits are reached or not (from generator voltage regulator), start value
Types.ActivePowerPuPMaxPu (from BaseGeneratorSignalNPQDiagram_INIT)Maximum active power in pu (base SnRef)
Types.ActivePowerPuPMinPu (from BaseGeneratorSignalNPQDiagram_INIT)Minimum active power in pu (base SnRef)
Types.ReactivePowerPuQMax0Pu (from BaseGeneratorSignalNPQDiagram_INIT)Start value of maximum reactive power in pu (base SnRef)
Types.ReactivePowerPuQMin0Pu (from BaseGeneratorSignalNPQDiagram_INIT)Start value of minimum reactive power in pu (base SnRef)
QStatusqStatus0 (from BaseGeneratorSignalNPQDiagram_INIT)Start voltage regulation status: standard, absorptionMax or generationMax