modelIBG_INIT
Initialization model for IBGs
Extends from Dynawo.Electrical.Sources.InjectorIDQ_INIT (Initialisation model for the injector controlled by d and q current components idPu and iqPu).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ApparentPowerModule | SNom (from InjectorIDQ_INIT) | Injector nominal apparent power in MVA | |
| Types.ActivePowerPu | P0Pu (from InjectorIDQ_INIT) | Start value of active power in pu (base SnRef) (receptor convention) | |
| Types.ReactivePowerPu | Q0Pu (from InjectorIDQ_INIT) | Start value of reactive power in pu (base SnRef) (receptor convention) | |
| Types.VoltageModulePu | U0Pu (from InjectorIDQ_INIT) | Start value of voltage amplitude at injector terminal in pu (base UNom) | |
| Types.Angle | UPhase0 (from InjectorIDQ_INIT) | Start value of voltage angle at injector terminal (in rad) | |
| Types.CurrentModulePu | IMaxPu | Maximum current of the injector in pu (base UNom, SNom) | |
| Types.VoltageModulePu | US1 | Lower voltage limit of deadband in pu (base UNom) | |
| Types.VoltageModulePu | US2 | Higher voltage limit of deadband in pu (base UNom) | |
| Real | kRCI | Slope of reactive current increase for low voltages in pu (base UNom, SNom) | |
| Real | kRCA | Slope of reactive current decrease for high voltages in pu (base UNom, SNom) | |
| Real | m | Current injection just outside of lower deadband in pu (base IMaxPu) | |
| Real | n | Current injection just outside of lower deadband in pu (base IMaxPu) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ComplexCurrentPu | i0Pu (from InjectorIDQ_INIT) | Start value of complex current at injector terminal in pu (base UNom, SnRef) (receptor convention) | |
| Types.PerUnit | Id0Pu (from InjectorIDQ_INIT) | Start value of id in pu (base SNom) (generator convention) | |
| Types.PerUnit | Iq0Pu (from InjectorIDQ_INIT) | Start value of iq in pu (base SNom) (generator convention) | |
| Types.ComplexApparentPowerPu | s0Pu (from InjectorIDQ_INIT) | Start value of complex apparent power at injector terminal in pu (base SnRef) (receptor convention) | |
| Types.ComplexVoltagePu | u0Pu (from InjectorIDQ_INIT) | Start value of complex voltage at injector terminal in pu (base UNom) |