modelLoadZIPFrequencyDependent

Extends from Modelica.Icons.Example (Icon for runnable examples).

Information

This test case consists in an Infinite Bus with variating voltage and frequency connected to a ZIP load with frequency dependence through a RL line. 

For the ZIP model, Zp=0.6, Ip=Pp=0.2 and Zq=Iq=0.2 and Pq=0.6; while sensitivity to frequency is defined as Kpf=2.0 and Kqd=-2.0.
Between t=2.0s and t=4.0s, the nominal voltage of the infinte bus decreases from 1.0 p..u. to 0.8 p.u.. Between t=6.0s and t=8.0s, the nominal frequency of the infinite bus increases from 1.0 p.u. to 1.05 p.u.







Components

TypeNameDefaultDescription
Electrical.Loads.LoadZIPFrequencyDependentloadZIPFrequencyDependent
Electrical.Buses.InfiniteBusWithVariationsinfiniteBusWithVariations
Electrical.Lines.Lineline
Modelica.Blocks.Sources.ConstantPRefPu
Modelica.Blocks.Sources.ConstantQRefPu
Modelica.Blocks.Sources.ConstantdeltaP
Modelica.Blocks.Sources.ConstantdeltaQ
Modelica.Blocks.Sources.ConstantomegaRefPu
Dynawo.Electrical.Buses.Busbus
Dynawo.Electrical.Loads.Load_INITload_INIT