| Name |
Description |
WPP4ACurrentSource2015 |
Wind Power Plant Type 4A model from IEC 61400-27-1:2015
standard with infinite bus - fault and reference tracking tests
(Active and reactive power steps) |
WPP4ACurrentSource2020 |
Wind Power Plant Type 4A model from IEC 61400-27-1:2020
standard with infinite bus - fault and reference tracking tests
(Active and reactive power steps) |
WPP4ACurrentSource2020FOCB |
Wind Power Plant Type 4A model from IEC 61400-27-1 standard
with infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WPP4BCurrentSource2020 |
Wind Power Plant Type 4B model from IEC 61400-27-1:2020
standard with infinite bus - fault and reference tracking tests
(Active and reactive power steps) |
WPP4BCurrentSource2020FOCB |
Wind Power Plant Type 4B model from IEC 61400-27-1:2020
standard with infinite bus - fault and reference tracking tests
(Active and reactive power steps) |
WPP4ACurrentSource2020UDip |
Wind Power Plant Type 4A model from IEC 61400-27-1:2020
standard with infinite bus - fault and reference tracking tests
(Active and reactive power steps) |
WT4ACurrentSource2015 |
Wind Turbine Type 4A model from IEC 61400-27-1:2015 standard
with infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WT4ACurrentSource2015FOCB |
Wind Turbine Type 4A model from IEC 61400-27-1:2015 standard
with infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WT4ACurrentSource2020 |
Wind Turbine Type 4A model from IEC 61400-27-1 standard with
infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WT4ACurrentSource2020FOCB |
Wind Turbine Type 4A model from IEC 61400-27-1:2020 standard
with infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WT4BCurrentSource2015 |
Wind Turbine Type 4B model from IEC 61400-27-1:2020 standard
with infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WT4BCurrentSource2015FOCB |
Wind Turbine Type 4B model from IEC 61400-27-1 standard with
infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WT4BCurrentSource2020 |
Wind Turbine Type 4B model from IEC 61400-27-1:2020 standard
with infinite bus - fault and reference tracking tests (Active and
reactive power steps) |
WT4BCurrentSource2020FOCB |
Wind Turbine Type 4B model from IEC 61400-27-1 standard with
infinite bus - fault and reference tracking tests (Active and
reactive power steps) |