modelTestGenset2
Ice, Generator, DriveTrain, all map-based
Information
This is model tests some of the genset features; it makes useage of maps on file.
The power request will not be entirely delivered by the DC terminals because of two reasons:
1. the requested power is the one delivered by the internal ICE, larger than the electrical power delivered by the internal generator, because the latter has, in general, a lower than one efficiency.
2. maximum DC power is also limited by parameter maxGenPow: in this simulation this limit is set to 55 kW and occurs 0.73 and 2.2 s.
To see this you can simultaneously plot trapezoid.y, genset.icePow.power, gsPow.power.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Electrical.Analog.Basic.Ground | ground1 | ||
| MapBased.Genset | genset | ||
| Modelica.Electrical.Analog.Sensors.PowerSensor | gsPow | ||
| Modelica.Electrical.Analog.Sources.ConstantVoltage | uDC | ||
| Modelica.Blocks.Sources.Trapezoid | trapezoid |