modelSMPMBrakingRectifier

SMPM braking an inertia

Extends from ElectricBraking.BaseModels.TranslationalExampleTemplate.

Information

A synchronous machine mechanically connected with a load inertia is initialized at nominal speed. The induced voltages (by the permanent magnets) are rectified (by a diode rectifier). Subsequently a switch is closed and the induced voltages drive the stator currents through stator resistances and stator inductances out of the machine and through the recticier, and through the external braking resistance. The internal and external losses are fed to a thermal capacitance, that increases the temperature. The amount of dissipated heat is equivalent to the kinetic energy of internal and external inertia.

Parameters

TypeNameDefaultDescription
ParameterRecords.ExperimentSettingsexperimentSettings (from TranslationalExampleTemplate)
Integerm3Number of phases
Realy2dc2*sin(pi/3)*sqrt(2)*sin(pi/6)/(pi/6)Factor DC&AC voltage
SI.ResistanceRb2*smpm.data.RsAC braking resistance
SI.ResistanceRbDCRb*y2dc^2/3Equivalent DC braking resistance

Components

TypeNameDefaultDescription
Modelica.Mechanics.Translational.Components.MassmassLoad (from TranslationalExampleTemplate)
Modelica.Thermal.HeatTransfer.Sensors.HeatFlowSensorheatFlowSensor (from TranslationalExampleTemplate)
Modelica.Blocks.Continuous.Integratorintegrator (from TranslationalExampleTemplate)
Modelica.Thermal.HeatTransfer.Components.HeatCapacitorheatCapacitor (from TranslationalExampleTemplate)
Modelica.Electrical.Analog.Basic.Groundground
Modelica.Electrical.Analog.Basic.ResistorbrakingResistor
Modelica.Electrical.Analog.Ideal.IdealClosingSwitchswitch
Modelica.Blocks.Sources.BooleanStepbooleanStep
Modelica.Electrical.Machines.Utilities.TerminalBoxterminalBox
Components.Smpmsmpm
Modelica.Electrical.PowerConverters.ACDC.DiodeBridge2mPulserectifier
Modelica.Electrical.Analog.Basic.Resistorearthing
Modelica.Electrical.Analog.Sensors.CurrentSensorcurrentSensor
Modelica.Mechanics.Translational.Components.IdealGearR2TidealGearR2T