modelES_BASIC

Parameters

TypeNameDefaultDescription
Basic settings
Realprobe_peak_amplitude0.1Peak amplitude of Probe
Modelica.SIunits.Frequencyprobe_frequency1Frequency of probe
Realintegrator_gain0.1Gain of integrator
Advanced settings
Modelica.SIunits.Anglephase_shift0Phase shift of the ES
Modelica.SIunits.Angledelay_compensation0Phase shift for compensating measurement delays
Integerorder_LPF1Order of LPF
Modelica.SIunits.Frequencyf_cutoff_LPF0.1*probe_frequencyCut-off frequency of LPF
Integerorder_HPF1Order of HPF
Modelica.SIunits.Frequencyf_cutoff_HPF0.1*probe_frequencyCut-off frequency of HPF

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputu
Modelica.Blocks.Interfaces.RealOutputy

Components

TypeNameDefaultDescription
Modelica.Blocks.Math.AddModulate
Modelica.Blocks.Sources.SineProbe
Modelica.Blocks.Math.ProductDemodulate
Modelica.Blocks.Sources.SineDemodulationSignal
Modelica.Blocks.Continuous.LowpassButterworthLPF_2
Modelica.Blocks.Continuous.FilterHPF
Modelica.Blocks.Continuous.IntegratorIntegrator