modelPartialHeatTransferZones

A partial heat transfer model with different HTC for liquid, two-phase and vapour

Extends from Greenhouses.Flows.FluidFlow.HeatTransfer.BaseClasses.PartialHeatTransfer (Basic component for partial heat transfer model).

Information

The partial model PartialHeatTransferZones extends the partial model PartialHeatTransfer and defines some inputs, that are needed to compute the convective heat transfer coefficient for a fluid flow:

  • Mdotnom = Nominal mass flow rate
  • Unom_l = Nominal heat transfer coefficient liquid side
  • Unom_tp = Nominal heat transfer coefficient two phase side
  • Unom_v = Nominal heat transfer coefficient vapor side
  • M_dot = Mass flow circulating in the pipe
  • x = vapor quality of the fluid

Parameters

TypeNameDefaultDescription
Integern (from PartialHeatTransfer)1Number of heat transfer segments

Connectors

TypeNameDefaultDescription
Greenhouses.Interfaces.Heat.ThermalPortLthermalPortL (from PartialHeatTransfer)

Components

TypeNameDefaultDescription
Medium.ThermodynamicStateFluidState (from PartialHeatTransfer)Thermodynamic states of flow segments
Modelica.Units.SI.HeatFluxq_dot (from PartialHeatTransfer)Heat flux
Modelica.Units.SI.TemperatureT_fluid (from PartialHeatTransfer)Medium.temperature(FluidState)Temperature of the fluid for the heat transfer process
Modelica.Units.SI.MassFlowRateMdotnomNomnial Mass flow rate
Modelica.Units.SI.CoefficientOfHeatTransferUnom_lNominal heat transfer coefficient liquid side
Modelica.Units.SI.CoefficientOfHeatTransferUnom_tpnominal heat transfer coefficient two phase side
Modelica.Units.SI.CoefficientOfHeatTransferUnom_vnominal heat transfer coefficient vapor side
Modelica.Units.SI.MassFlowRateM_dotInlet massflow
RealxVapor quality