modelPdrop
Linear pressure drop
Extends from Greenhouses.Icons.Water.PressDrop.
Information
This very simple model assumes a non-compressible flow for computing the pressure drop
This model is an adapted version of the model Pdrop from ThermoCycle Library. In order to make it compatible with the Greenhouses library, the fluid ports have been replaced by the Modelica Standard Library fluidPort.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| PressureDrops | DPtype | PressureDrops.UD | |
| Modelica.Units.SI.MassFlowRate | Mdot_max | 0.1 | flow rate at DELTAp_max |
| Modelica.Units.SI.Pressure | DELTAp_max | 20E5 | Pressure drop at Mdot_max |
| Initialization | |||
| Modelica.Units.SI.Pressure | p_su_start | 1e5 | Inlet pressure start value |
| Modelica.Units.SI.Pressure | DELTAp_start | 10000 | Start value for the pressure drop |
| Modelica.Units.SI.MassFlowRate | Mdot_start | 0.1 | Mass flow rate initial value |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Fluid.Interfaces.FluidPort_a | InFlow | ||
| Modelica.Fluid.Interfaces.FluidPort_b | OutFlow |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.MassFlowRate | Mdot | ||
| Modelica.Units.SI.Pressure | DELTAp |
Contents
| Name | Description |
|---|---|