modelPdrop

Linear pressure drop

Extends from Greenhouses.Icons.Water.PressDrop.

Information

This very simple model assumes a non-compressible flow for computing the pressure drop

This model is an adapted version of the model Pdrop from ThermoCycle Library. In order to make it compatible with the Greenhouses library, the fluid ports have been replaced by the Modelica Standard Library fluidPort.

Parameters

TypeNameDefaultDescription
PressureDropsDPtypePressureDrops.UD
Modelica.Units.SI.MassFlowRateMdot_max0.1flow rate at DELTAp_max
Modelica.Units.SI.PressureDELTAp_max20E5Pressure drop at Mdot_max
Initialization
Modelica.Units.SI.Pressurep_su_start1e5Inlet pressure start value
Modelica.Units.SI.PressureDELTAp_start10000Start value for the pressure drop
Modelica.Units.SI.MassFlowRateMdot_start0.1Mass flow rate initial value

Connectors

TypeNameDefaultDescription
Modelica.Fluid.Interfaces.FluidPort_aInFlow
Modelica.Fluid.Interfaces.FluidPort_bOutFlow

Components

TypeNameDefaultDescription
Modelica.Units.SI.MassFlowRateMdot
Modelica.Units.SI.PressureDELTAp

Contents

NameDescription
Medium