modelSinkP
Pressure sink
Extends from Greenhouses.Icons.Water.SourceP.
Information
Model SinkP sets the boundary pressure of the fluid flowing from the port to the model (i.e. into the model).
Note that boundary pressure is imposed by the model if the fluid is flowing into the model. If flow reversal happens (i.e. mass flow flowing out og SinkP) then the boundary enthalpy is also imposed by the model.
The pressure and enthalpy can be set as parameters or defined by the connector.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Pressure | p0 | 1.01325e5 | Nominal pressure |
| Modelica.Units.SI.SpecificEnthalpy | h | 1e5 | Nominal specific enthalpy |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | in_p0 | ||
| Modelica.Blocks.Interfaces.RealInput | in_h | ||
| Modelica.Fluid.Interfaces.FluidPort_b | flangeB |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Pressure | p |
Contents
| Name | Description |
|---|---|