.IBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.Data.PipeDataAIT151218

Information

Overview

This record contains data of a real disitrict heating network for week-long period (23-29 Januar 2009) monitored by the Austrian Institut for Technology.

Pipes are layed underground

Data structure

Column 1: Time in s

Column 2: Temperature in point 1 in K

Column 3: Temperature in point 2 in K

Column 4: Temperature in point 3 in K

Column 5: Temperature in point 4 in K

Column 6: Mass flow rate in point 1 in kg/s

Column 7: Mass flow rate in point 2 in kg/s

Column 8: Mass flow rate in point 3 in kg/s

Column 9: Mass flow rate in point 4 in kg/s

Column 10: Outdoor temperature in K

Test procedure

Information at several points of the district heating network is recorded during a week.

Test bench schematic

Schematic of test district heating network in Pongau

Notice that length are approximated

Pipe characteristics

Revisions


Generated at 2024-12-24T19:25:53Z by OpenModelicaOpenModelica 1.24.3 using GenerateDoc.mos