recordPipeDataAIT151218
Extends from BaseClasses.PipeDataBaseDefinition (BaseClass for experimental data from the pipe test bench).
Information
Overview
This record contains data of a real disitrict heating network for week-long period (23-29 Januar 2009) monitored by the Austrian Institut for Technology.
Pipes are layed underground
Data structure
Column 1: Time in s
Column 2: Temperature in point 1 in K
Column 3: Temperature in point 2 in K
Column 4: Temperature in point 3 in K
Column 5: Temperature in point 4 in K
Column 6: Mass flow rate in point 1 in kg/s
Column 7: Mass flow rate in point 2 in kg/s
Column 8: Mass flow rate in point 3 in kg/s
Column 9: Mass flow rate in point 4 in kg/s
Column 10: Outdoor temperature in K
Test procedure
Information at several points of the district heating network is recorded during a week.Test bench schematic
Notice that length are approximated
Pipe characteristics
- Inner diameter: 0.0825 m (DN080)
- Outer diameter: 0.0889 m (stell wall thickness 3.2 mm)
- Casing diameter: 0.18 m
- Insulation material: Polyurethane
- Heat conductivity of insulation material: 0.024 W/(m K) (average value at 50 °C)
- Length specific pipe's heat loss coefficient: 0.208 W/(m K)
- Wall roughness coefficient: 0.1 mm
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | n (from PipeDataBaseDefinition) | Number of measurement data point | |
| Real | data (from PipeDataBaseDefinition) | Time in s | measure 1 | measure 2 | ... | measure n | |
Revisions
-
December 18, 2015 by Daniele Basciotti:
First implementation.