recordefficiencyParameters

Record for efficiency parameters

Extends from Modelica.Icons.Record (Icon for records).

Information

Data record for performance data that describe volume flow rate versus efficiency. The volume flow rate r_V must be increasing, i.e., r_V[i] < r_V[i+1]. Both vectors, r_V and eta must have the same size.

Parameters

TypeNameDefaultDescription
Modelica.SIunits.VolumeFlowRate[:]V_flowVolumetric flow rate at user-selected operating points
Modelica.SIunits.Efficiency[size(V_flow, 1)]etaFan or pump efficiency at these flow rates

Revisions

  • September 28, 2011, by Michael Wetter:
    First implementation.