modelPartialSource_T

Boundary with prescribed temperature

Extends from IBPSA.Fluid.Sources.BaseClasses.PartialSource (Partial component source with one fluid connector).

Information

Partial model that defines ports.h_outflow using an optional input for the temperature. Otherwise the parameter value is used.

Parameters

TypeNameDefaultDescription
IntegernPorts (from PartialSource)0Number of ports
Advanced
BooleanverifyInputs (from PartialSource)falseSet to true to stop the simulation with an error if the medium temperature is outside its allowable range
Conditional inputs
Booleanuse_T_infalseGet the temperature from the input connector
Fixed inputs
Medium.TemperatureTMedium.T_defaultFixed value of temperature

Connectors

TypeNameDefaultDescription
Modelica.Fluid.Interfaces.FluidPorts_b[nPorts]ports (from PartialSource)
Modelica.Blocks.Interfaces.RealInputT_inPrescribed boundary temperature

Revisions

  • February 2nd, 2018 by Filip Jorissen
    Initial version for refactoring inputs of sources. See #882.