modelPartialVDI6007
Partial model for equivalent air temperature as defined in VDI 6007 Part 1
Information
PartialVDI6007 is a partial model for EquivalentAirTemperature
models.
Parameters
| Type | Name | Default | Description |
| Modelica.SIunits.Emissivity | aExt | | Coefficient of absorption of exterior walls (outdoor) |
| Integer | n | | Number of orientations (without ground) |
| Real[n] | wfWall | | Weight factors of the walls |
| Real[n] | wfWin | | Weight factors of the windows |
| Real | wfGro | | Weight factor of the ground (0 if not considered) |
| Modelica.SIunits.Temperature | TGro | | Temperature of the ground in contact with floor plate |
| Modelica.SIunits.CoefficientOfHeatTransfer | alphaWallOut | | Exterior walls convective coefficient of heat transfer (outdoor) |
| Modelica.SIunits.CoefficientOfHeatTransfer | alphaRad | | Coefficient of heat transfer for linearized radiation |
| Boolean | withLongwave | true | Set to true to include longwave radiation exchange |
Components
| Type | Name | Default | Description |
| Modelica.SIunits.Temperature[n] | TEqWall | | Equivalent wall temperature |
| Modelica.SIunits.Temperature[n] | TEqWin | | Equivalent window temperature |
| Modelica.SIunits.TemperatureDifference | delTEqLW | | Equivalent long wave temperature |
| Modelica.SIunits.TemperatureDifference | delTEqLWWin | | Equivalent long wave temperature for windows |
| Modelica.SIunits.TemperatureDifference[n] | delTEqSW | | Equivalent short wave temperature |