modelMultiLayer
Unit test for multi layer model
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
This model is a unit test for the IDEAS.Buildings.Components.BaseClasses.ConductiveHeatTransfer.MultiLayer model.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Area | A | 10 | total multilayer area |
| IDEAS.Buildings.Data.Constructions.CavityWallPartialFill | cavityWallData | Record containing data for cavity wall | |
| IDEAS.Buildings.Data.Constructions.TABS | tabsData | Record containing tabs construction data |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| IDEAS.Buildings.Components.BaseClasses.ConductiveHeatTransfer.MultiLayer | cavityWall | Test model containing an air layer | |
| Modelica.Thermal.HeatTransfer.Sources.FixedTemperature | fixTem | Temperature boundary condition | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature | prescribedTemperature | ||
| Modelica.Blocks.Sources.Ramp | ramp | ||
| IDEAS.Buildings.Components.BaseClasses.ConductiveHeatTransfer.MultiLayer | TABS | Test model containing only solid layers |
Revisions
-
January 30, 2019 by Filip Jorissen:
Revised initial conditions according to new implementation ofMultiLayer. -
May 15, 2018 by Filip Jorissen:
Fixed initial conditions. -
January 18, 2017 by Filip Jorissen:
First implementation