modelMultiLayerRamp
Unit test for multi layer model
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
This model is a unit test for the IDEAS.Buildings.Components.BaseClasses.ConductiveHeatTransfer.MultiLayer model. It verifies whether the total energy contained by a multi layer model is correct.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Area | A | 10 | total multilayer area |
| Modelica.Units.SI.TemperatureDifference | dT | 20 | Temperature difference of the ramp |
| IDEAS.Buildings.Data.Constructions.ConcreteSlab | concreteFloor | Record containing tabs construction data |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Temperature | dT_Avg | ||
| Modelica.Units.SI.Energy | Etot | ||
| Modelica.Units.SI.Energy | Enet_layMul | ||
| Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature | preTem | Prescribed temperature | |
| Modelica.Blocks.Sources.Ramp | ramp | ||
| IDEAS.Buildings.Components.BaseClasses.ConductiveHeatTransfer.MultiLayer | layMul | Multi layer model | |
| Modelica.Thermal.HeatTransfer.Components.ThermalConductor | theCon | For being able to use fixedInitial without addRes_b = true |
Revisions
-
March 7, 2017 by Filip Jorissen:
First implementation