modelZoneLwDistributionViewFactor

Internal longwave radiative heat exchange using view factors

Information

Computation of longwave radiative heat exchange based on view factors.

Assumption and limitations

This implementation is only valid for rectangular geometries.

Verification

Verification test in IDEAS.Buildings.Validation.Tests.ViewFactorVerification.

Parameters

TypeNameDefaultDescription
IntegernSurfnumber of surfaces in contact with the zone
Modelica.Units.SI.AngleincCeilingIDEAS.Types.Tilt.Ceiling
Modelica.Units.SI.AngleincFloorIDEAS.Types.Tilt.Floor
Modelica.Units.SI.AngleincWallIDEAS.Types.Tilt.Wall
Modelica.Units.SI.AngleaziSouthIDEAS.Types.Azimuth.S
IntegernumAzi4
Modelica.Units.SI.LengthhZoneDistance between floor and ceiling
BooleanlinearisetrueLinearise radiative heat exchange
RealUmat
Linearisation
Modelica.Units.SI.TemperatureTzone_nom295.15Nominal temperature of environment, used for linearisation
Modelica.Units.SI.TemperatureDifferencedT_nom-2Nominal temperature difference between solid and air, used for linearisation
Advanced
RealvieFacEmissivity weighted viewfactor from surface to surface
RealvieFacTotEmissivity weighted viewfactor from total of surfaces to each other

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputincSurface inclination angles
Modelica.Blocks.Interfaces.RealInputaziSurface azimuth angles
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_aport_a
Modelica.Blocks.Interfaces.RealInputAsurface areas
Modelica.Blocks.Interfaces.RealInputepsLwlongwave surface emissivities
Modelica.Blocks.Interfaces.RealOutputfloorAreaAmount of floor area for each surface

Revisions

  • December 8, 2016 by Filip Jorissen:
    Fixed indexing bug in algorithm.