This occupancy model assumes a constant latent and sensible load per person.
We assume this heat gain is caused by the metabolic combustion of suger,
resulting into a corresponding CO2 production.
The CO2 mass flow rate is added only if the Medium contains CO2.
Latent heat is only added if the Medium is a moist air medium.
Sensible heat is emitted both as convective and radiant heat using a fixed weighing factor.
-