modelSim

Switches between n50Tight or AirTight based on interzonalAirFlowType in SimInfoManager

Extends from IDEAS.Buildings.Components.InterzonalAirFlow.BaseClasses.PartialInterzonalAirFlown50 (Model representing idealised n50 air leakage).

Information

Parameters

TypeNameDefaultDescription
IntegernPorts (from PartialInterzonalAirFlow)Number of ports for connection to zone air volume
IntegernPortsExt (from PartialInterzonalAirFlow)Number of ports for connection to zone air volume
Modelica.Units.SI.VolumeV (from PartialInterzonalAirFlow)Zone air volume for n50 computation
Realn50 (from PartialInterzonalAirFlow)n50 value
Realn50_int (from PartialInterzonalAirFlow)n50Internal n50 value
BooleanprescribesPressure (from PartialInterzonalAirFlow)falseIndication whether this model prescribes the air zone pressure or not
BooleanverifyBothPortsConnected (from PartialInterzonalAirFlow)false=true, to verify fluid port connections
Advanced
Realn50toAch (from PartialInterzonalAirFlow)20Conversion fractor from n50 to Air Change Rate
Modelica.Units.SI.MassFlowRatem_flow_nominal_vent (from PartialInterzonalAirFlow)Nominal mass flow rate of ventilation system
Modelica.Units.SI.MassFlowRatem_flow_nominal_airLea (from PartialInterzonalAirFlown50)V*rho_default/3600*n50_int/n50toAchNominal mass flow of air leakage

Connectors

TypeNameDefaultDescription
Modelica.Fluid.Interfaces.FluidPort_bport_b_interior (from PartialInterzonalAirFlow)Port a connection to zone air model ports
Modelica.Fluid.Interfaces.FluidPort_aport_a_interior (from PartialInterzonalAirFlow)Port b connection to zone air model ports
Modelica.Fluid.Interfaces.FluidPort_aport_a_exterior (from PartialInterzonalAirFlow)Port a connection to model exterior ports
Modelica.Fluid.Interfaces.FluidPort_bport_b_exterior (from PartialInterzonalAirFlow)Port b connection to model exterior ports
Modelica.Fluid.Interfaces.FluidPorts_aports (from PartialInterzonalAirFlow)Ports connector for multiple ports
Modelica.Fluid.Interfaces.FluidPorts_bportsExt (from PartialInterzonalAirFlow)Ports connector for multiple ports

Components

TypeNameDefaultDescription
BoundaryConditions.SimInfoManagersim (from PartialInterzonalAirFlowBoundary)Simulation information manager
IDEAS.Fluid.Sources.OutsideAirbou (from PartialInterzonalAirFlowBoundary)Boundary model
Modelica.Blocks.Sources.RealExpressionreaExpMflo (from PartialInterzonalAirFlown50)
Fluid.Interfaces.IdealSourceairInfiltration (from PartialInterzonalAirFlown50)Fixed air infiltration rate
Fluid.Interfaces.IdealSourceairExfiltrationFixed air exfiltration rate

Revisions

  • March 17, 2020, Filip Jorissen:
    Added support for vector fluidport. See #1029.
  • January 25, 2019, Filip Jorissen:
    Added constant prescribesPressure that indicates whether this model prescribes the zone air pressure or not. See #971.
  • April 27, 2018 by Filip Jorissen:
    First version. See #796.