modelWindowOrientations

Comparison incident solar irradiation for three window orientations

Extends from Modelica.Icons.Example (Icon for runnable examples).

Information

This model verifies whether upward, downward and vertical orientations lead to correct values for the diffuse and direct solar irradiations. I.e. the diffuse ground component for upward directions should be zero. The diffuse sky component for downward directions should be zero.

Components

TypeNameDefaultDescription
BoundaryConditions.SimInfoManagersim
WindowwinWalWindow with wall orientation
Zonezone1
WindowwinFloWindow with floor orientation
WindowwinCeiWindow with ceiling orientation

Contents

NameDescription
Medium

Revisions

  • January 26, 2018, by Filip Jorissen:
    First implementation.