.IDEAS.Fluid.BaseClasses.FlowModels.Validation.BasicFlowFunction_m_flow_DerivativeCheck2

Model that checks the correct implementation of the 2nd order derivative of the flow function

Information

This model validates the implementation of IDEAS.Fluid.BaseClasses.FlowModels.basicFlowFunction_m_flow and its second order derivative IDEAS.Fluid.BaseClasses.FlowModels.basicFlowFunction_m_flow_der2. If the derivative implementation is wrong, the simulation will stop with an error.

Implementation

The mass flow rate m_flow is increased non-linearly in order for the first and second derivatives in IDEAS.Fluid.BaseClasses.FlowModels.basicFlowFunction_m_flow_der2 to be non-zero during part of the simulation. This will ensure full code coverage of this function.

Revisions


Generated at 2025-04-09T18:19:57Z by OpenModelicaOpenModelica 1.25.0 using GenerateDoc.mos