modelModulationSecurity

Non physical down modulation of the power of a heat production when the fluid temperature approach its boundaries temperature in order to reduce the number of events

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureDifferencedeltaT_securityif use_modulation_security then 1 else 5Temperature difference from the boundary at which the security hysteresis will be released
Modelica.Units.SI.TemperatureT_max373.15Maximum fluid temperature
Modelica.Units.SI.TemperatureT_min273.15Minimum fluid temperature
Advanced › Events
Booleanuse_modulation_securityfalseSet to true if power modulation should be used to avoid exceeding temperature.

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutputmodulation_securityIDEAS.Utilities.Math.Functions.spliceFunction(x = min(limLow.y, limUp.y)/max(Modelica.Constants.eps, deltaT_security) - 1, pos = 1, neg = 0, deltax = 0.5)Modulation to avoid reaching temperature boundaries