recordCN_Jonas2018
Parameter set for a covered, non-insulated PVT collector based on Jonas et al. (2018)
A record of IDEAS.Fluid.PVTCollectors.Data.GenericQuasiDynamic.
Information
This record contains thermal and electrical parameters for a covered PVT collector without rear insulation, based on experimental identification results from Jonas et al. (2018). These parameters were used in the validation of a TRNSYS PVT collector model under ISO 9806:2013 quasi-dynamic conditions.
This record can be used as a generic representation of a covered, non-insulated PVT collector. However, if you know the brand and model of the PVT collector you plan to simulate or install, it is recommended to use the actual datasheet parameters in a custom IDEAS.Fluid.PVTCollectors.Data.GenericQuasiDynamic record.
References
- Jonas, D., Theis, D., Frey, G. (2018). Implementation and Experimental Validation of a Photovoltaic-Thermal (PVT) Collector Model in TRNSYS. EuroSun 2018. DOI: 10.18086/eurosun2018.02.16
Attributes
| Name | Value |
|---|---|
| A final | 1.79 |
| CTyp final | IDEAS.Fluid.SolarCollectors.Types.HeatCapacity.TotalCapacity |
| C final | 16075*1.79 |
| V final | 5/1000 |
| mDry final | 24 |
| mperA_flow_nominal final | 0.03 |
| dp_nominal final | 60000 |
| incAngDat final | Modelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 90}) |
| incAngModDat final | {1, 1, 0.99, 0.98, 0.97, 0.95, 0.92, 0.88, 0.00} |
| colTyp final | IDEAS.Fluid.PVTCollectors.Types.CollectorType.Covered |
| IAMDiff final | 0.93 |
| eta0 final | 0.596 |
| c1 final | 6.583 |
| c2 final | 0.021 |
| c3 final | 0.000 |
| c4 final | 0.066 |
| c6 final | 0.009 |
| P_nominal final | 280 |
| gamma final | -0.00370 |
| etaEl final | 0.1406 |
Revisions
-
July 7, 2025, by Lone Meertens:
First implementation PVT model. This is for #1436.