This record contains anonymized thermal and electrical performance parameters for an uncovered photovoltaic–thermal (PVT) collector with rear insulation, tested under ISO 9806:2013 quasi-dynamic conditions. Thermal performance parameters correspond to operation of the PVT collector at maximum power point (MPP mode).
This datasheet is used in the validation of IDEAS.Fluid.PVTCollectors.PVTQuasiDynamicCollector, which can be found in the IDEAS.Fluid.PVTCollectors.Validation.PVT_UI package.
record UI_Validation = IDEAS.Fluid.PVTCollectors.Data.GenericQuasiDynamic(final A = 1.66, final CTyp = IDEAS.Fluid.SolarCollectors.Types.HeatCapacity.TotalCapacity, final C = 42200*1.66, final V = 5/1000, final mDry = 28, final mperA_flow_nominal = 0.03, final dp_nominal = 60000, final incAngDat = Modelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 90}), final incAngModDat = {1, 1, 1, 0.99, 0.99, 0.98, 0.96, 0.92, 0.00}, final colTyp = IDEAS.Fluid.PVTCollectors.Types.CollectorType.Uncovered, final IAMDiff = 1, final eta0 = 0.475, final c1 = 7.411, final c2 = 0.0, final c3 = 1.7, final c4 = 0.437, final c6 = 0.003, final P_nominal = 280, final gamma = -0.0041, final etaEl = 0.1687);