recordUN_Validation

Parameters for an uncovered flat-plate PVT collector without rear cover or back-side insulation

A record of IDEAS.Fluid.PVTCollectors.Data.GenericQuasiDynamic.

Information

This record contains performance parameters for a flat‑plate, uncovered and uninsulated PVT collector, derived from manufacturer datasheets and thermal rating documentation. Thermal parameters follow the ISO 9806:2013 quasi‑dynamic format and correspond to operation at the PV module’s maximum power point (MPP).

The thermal coefficients were originally obtained using the ISO 9806:2013 unglazed steady-state method, and converted to quasi‑dynamic form according to the procedure detailed in SKN-N0474R0: Thermal Performance Parameter Conversion to ISO 9806-2017.

For this PVT collector, additional real-life measurement data is publicly available (Veynandt, 2023) and has been used in the validation of IDEAS.Fluid.PVTCollectors.PVTQuasiDynamicCollector, which can be found in the IDEAS.Fluid.PVTCollectors.Validation.PVT_UN package.

Certificate

References

Attributes

NameValue
A final1.64
CTyp finalIDEAS.Fluid.SolarCollectors.Types.HeatCapacity.TotalCapacity
C final22100*1.64
V final1.54/1000
mDry final30
mperA_flow_nominal final0.02
dp_nominal final300000
incAngDat finalModelica.Units.Conversions.from_deg({0, 10, 20, 30, 40, 50, 60, 70, 80, 90})
incAngModDat final{1, 1, 1, 1, 0.99, 0.97, 0.92, 0.80, 0.55, 0.00}
colTyp finalIDEAS.Fluid.PVTCollectors.Types.CollectorType.Uncovered
IAMDiff final0.93
eta0 final0.535
c1 final10.74
c2 final0.0
c3 final1.0997
c4 final0.535*0.85*(1 - 3*0.067)
c6 final0.067*0.535
P_nominal final300
gamma final-0.00375
etaEl final0.183