modelTap

Model for a DHW tap, reading the DHW demand via a RealInput connector.

Extends from IDEAS.Fluid.Taps.BaseClasses.PartialTap (Partial model for a (DHW) tap).

Information

Description

Model of a domestic hot water (DHW) tap. The tap is modelled as a thermostatic mixing valve.

The input mDHWSet is a RealInput to connect the prescribed DHW mass flow rate (in [kg/s]) at the desired TSet temperature.

See IDEAS.Fluid.Taps.BaseClasses.PartialTap for more information.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureTSet (from PartialTap)318.15Temperature setpoint of DHW at the tap
Modelica.Units.SI.TemperatureTCol (from PartialTap)283.15Temperature of cold supply water
Assumptions
BooleanallowFlowReversal (from PartialTwoPort)true= false to simplify equations, assuming, but not enforcing, no flow reversal
Nominal condition
Modelica.Units.SI.MassFlowRatem_flow_nominal (from PartialTwoPortInterface)Nominal mass flow rate
Advanced
Modelica.Units.SI.MassFlowRatem_flow_small (from PartialTwoPortInterface)1E-4*abs(m_flow_nominal)Small mass flow rate for regularization of zero flow
Advanced › Diagnostics
Booleanshow_T (from PartialTwoPortInterface)false= true, if actual temperature at port is computed

Connectors

TypeNameDefaultDescription
Modelica.Fluid.Interfaces.FluidPort_aport_a (from PartialTwoPort)Fluid connector a (positive design flow direction is from port_a to port_b)
Modelica.Fluid.Interfaces.FluidPort_bport_b (from PartialTwoPort)Fluid connector b (positive design flow direction is from port_a to port_b)
Modelica.Blocks.Interfaces.BooleanOutputDHWCom (from PartialTap)Boolean output signal to indicate whether there is DHW comfort (true) or discomfort (false)
Modelica.Blocks.Interfaces.RealInputmFloSetMass flowrate of DHW at TSet in kg/s

Components

TypeNameDefaultDescription
Modelica.Units.SI.MassFlowRatem_flow (from PartialTwoPortInterface)port_a.m_flowMass flow rate from port_a to port_b (m_flow > 0 is design flow direction)
Modelica.Units.SI.PressureDifferencedp (from PartialTwoPortInterface)port_a.p - port_b.pPressure difference between port_a and port_b
Medium.ThermodynamicStatesta_a (from PartialTwoPortInterface)if allowFlowReversal then Medium.setState_phX(port_a.p, noEvent(actualStream(port_a.h_outflow)), noEvent(actualStream(port_a.Xi_outflow))) else Medium.setState_phX(port_a.p, noEvent(inStream(port_a.h_outflow)), noEvent(inStream(port_a.Xi_outflow)))Medium properties in port_a
Medium.ThermodynamicStatesta_b (from PartialTwoPortInterface)if allowFlowReversal then Medium.setState_phX(port_b.p, noEvent(actualStream(port_b.h_outflow)), noEvent(actualStream(port_b.Xi_outflow))) else Medium.setState_phX(port_b.p, noEvent(port_b.h_outflow), noEvent(port_b.Xi_outflow))Medium properties in port_b
IDEAS.Fluid.Interfaces.IdealSourcemFloSouHot (from PartialTap)Ideal mass flow source to model the hot water offtake from the system
IDEAS.Fluid.Sources.Boundary_pTbouHot (from PartialTap)Sink to model the hot water offtake from the system
Modelica.Blocks.Sources.RealExpressionTCol_in (from PartialTap)Temperature of the cold water injected into the system
IDEAS.Fluid.Sources.Boundary_pTbouCol (from PartialTap)Supply to model the cold water injection into the system
IDEAS.Fluid.Interfaces.IdealSourcemFloSouCol (from PartialTap)Ideal mass flow source to model the cold water injection into the system
Modelica.Blocks.Sources.RealExpressionmFloHot (from PartialTap)Required flow rate from the hot water source
IDEAS.Fluid.Sensors.TemperatureTwoPortTHot (from PartialTap)Temperature sensor
Modelica.Blocks.Logical.GreaterEqualThresholdcom (from PartialTap)Block operator to check whether there is DHW comfort or not. True = comfort, false = discomfort.

Revisions

  • March 26, 2024, by Lucas Verleyen:
    First implementation, adopted from depreciated model.
    See #1287 for more information.